Numerical Protection Relay

Home / Numerical Protection Relay

Application

The numeric relays are mostly used in the generating stations and substations for automated protection. These relays can protect various components such as feeder, Motor, Generator, Transmission line, Transformers and Bus bars.

Models

SL NoModels
1Numerical Over Current Relay
1 ɸ - EOC01
  • Configurable 7 IDMT + 1 Definite Time curves
  • 1 phase over current protection (ANSI CODE: 50/51)
3 ɸ- EOC03 - (Basic/Advanced)
  • Configurable 7 IDMT + 1 Definite Time curves
  • 1 phase over current protection (ANSI CODE: 50/51)
2Numerical Directional Over Current Relay
1ɸ - EOC11D - Basic/Advanced
  • Configurable 7 IDMT + 1 Definite Time curves
  • 1 phase over current protection (ANSI CODE: 50/51)
3ɸ - EOC33D - Basic/Advanced
  • Configurable 7 IDMT + 1 Definite Time curves
  • 3 phase Directional over current protection
  • (ANSI CODE: 67/50/51)
3Numerical Voltage Relay
Over Voltage (1ɸ/3ɸ) - EOV10/ EOV30 -Basic/Advanced
  • Configurable 3 IDMT + 1 Definite Time curves
  • Single phase over voltage protection
  • Configurable 3 IDMT + 1 Definite Time curves
  • 3 phases over voltage protection (ANSI CODE: 59)
Under Voltage(1ɸ/3ɸ) -EUV10/ EUV30 - Basic/Advanced
  • Configurable 3 IDMT + 1 Definite Time curves
  • Single phase under voltage protection
  • Configurable 3 IDMT + 1 Definite Time curves
  • 3 phases under voltage protection (ANSI CODE: 59)
Over & Under Voltage (1ɸ) - EUO10 - Basic
  • Configurable 3 IDMT + 1 Definite Time curves for overvoltage
  • Configurable 1 IDMT + 1 Definite Time curves for undervoltage
  • Single phase over voltage protection
  • Single phase under voltage protection
4Numerical Transformer Differential Relay
1ɸ - ETD02 - Basic /Advanced
  • Configurable Dual Slope
  • Characteristic
  • Transformer Differential Protection
  • (ANSI CODE: 87)
5Numerical Distance Relay
1ɸ - ELP11 - Basic /Advanced
  • Configurable 7 IDMT + 1 Definite Time curves
  • Single phase Over Voltage
  • Single Phase Line Protection with Quadrilateral Characteristic
6Numerical Voltage/Current Negative Sequence Relay
Voltage - ENS30 - Basic/Advanced
  • Negative phase sequence voltage protection (ANSI CODE: 47)
  • Under voltage protection (ANSI CODE: 27) - Optional
  • Over voltage protection (ANSI CODE: 59)- Optional
  • Negative phase sequence current protection (ANSI CODE: 46)
Current - ENS03 - Basic/Advanced
  • Over current protection
  • (ANSI CODE: 50/51)- Optional
7Numerical Frequency Relay
3ɸ - EFR10 - Basic/Advanced
  • 3 phase over/under frequency protection
8Numerical over/under power factor relay
3ɸ - EPF33 - Basic/Advanced
  • Field Configurable CT Secondary 1A or 5A
  • 3 phases over power factor protection
  • 3 phases under power factor protection
9Numerical Over Current/Earth Fault Relay
3ɸ - EPE04 - Basic/Advanced
  • Configurable 7 IDMT + 1 Definite Time curves
  • 3 phase over current and earth fault protection (ANSI CODE: 50/51N)

Configurable 7 IDMT + 1 Definite Time Curves

  1. Normal Inverse
  2. Extremely Inverse
  3. Very Inverse
  4. Restricted Inverse
  5. 3 Sec Delay
  6. 1.3 Sec Delay
  7. Long Time Delay
  8. Definite Time

Configurable 3 IDMT + 1 Definite Time curves

  1. 3 Sec Delay
  2. 1.3Sec Delay
  3. Long Time Delay
  4. Definite Time

Configurable 3 IDMT + 1 Definite Time curves

  1. Extremely Inverse
  2. Definite Time